Dosage and administration
Pregnancy must be ruled out prior to administration of Prolia. Before initiating Prolia in patients with advanced chronic kidney disease, including dialysis patients, evaluate for the presence of chronic kidney disease mineral and bone disorder with intact parathyroid hormone, serum calcium, 25(OH) vitamin D, and 1,25(OH) 2 vitamin D. Prolia should be administered by a healthcare provider. Administer 60 mg every 6 months as a subcutaneous injection in the upper arm, upper thigh, or abdomen. Instruct patients to take calcium 1000 mg daily and at least 400 IU vitamin D daily.
2.1 Pregnancy
Testing Prior to Initiation of Prolia Pregnancy must be ruled out prior to administration of Prolia. Perform pregnancy testing in all females of reproductive potential prior to administration of Prolia. Based on findings in animals, Prolia can cause fetal harm when administered to pregnant women.
2.2 Laboratory
Testing in Patients with Advanced Chronic Kidney Disease Prior to Initiation of Prolia In patients with advanced chronic kidney disease [i.e., estimated glomerular filtration rate (eGFR) < 30 mL/min/1.73 m 2 ], including dialysis-dependent patients, evaluate for the presence of chronic kidney disease-mineral and bone disorder (CKD-MBD) with intact parathyroid hormone (iPTH), serum calcium, 25(OH) vitamin D, and 1,25 (OH) 2 vitamin D prior to decisions regarding Prolia treatment. Consider also assessing bone turnover status (serum markers of bone turnover or bone biopsy) to evaluate the underlying bone disease that may be present.
2.3 Recommended
Dosage Prolia should be administered by a healthcare provider. The recommended dose of Prolia is 60 mg administered as a single subcutaneous injection once every 6 months. Administer Prolia via subcutaneous injection in the upper arm, the upper thigh, or the abdomen. All patients should receive calcium 1000 mg daily and at least 400 IU vitamin D daily. If a dose of Prolia is missed, administer the injection as soon as the patient is available. Thereafter, schedule injections every 6 months from the date of the last injection.
2.4 Preparation and
Administration Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. Prolia is a clear, colorless to pale yellow solution that may contain trace amounts of translucent to white proteinaceous particles. Do not use if the solution is discolored or cloudy or if the solution contains many particles or foreign particulate matter. Prior to administration, Prolia may be removed from the refrigerator and brought to room temperature up to 25°C (77°F) by standing in the original container. This generally takes 15 to 30 minutes. Do not warm Prolia in any other way. Instructions for Administration of Prolia Prefilled Syringe with Needle Safety Guard IMPORTANT: In order to minimize accidental needlesticks, the Prolia single-dose prefilled syringe will have a green safety guard; manually activate the safety guard after the injection is given. DO NOT slide the green safety guard forward over the needle before administering the injection; it will lock in place and prevent injection. Activate the green safety guard (slide over the needle) after the injection.
Step 1: Remove Gray Needle Cap Remove needle cap.
Step 2: Administer Subcutaneous Injection Choose an injection site. The recommended injection sites for Prolia include: the upper arm OR the upper thigh OR the abdomen. Insert needle and inject all the liquid subcutaneously. Do not administer into muscle or blood vessel. DO NOT put gray needle cap back on needle.
Step 3: Immediately Slide Green Safety Guard Over Needle With the needle pointing away from you. Hold the prefilled syringe by the clear finger grip with one hand. Then, with the other hand, grasp the green safety guard by its base and gently slide it towards the needle until the green safety guard locks securely in place and/or you hear a "click". DO NOT grip the green safety guard too firmly - it will move easily if you hold and slide it gently. Hold clear finger grip. Gently slide green safety guard over needle and lock securely in place. Do not grip green safety guard too firmly when sliding over needle. Immediately dispose of the syringe and needle cap in the nearest sharps container. DO NOT put the needle cap back on the used syringe. Image Image Image Image Image Image Image
Text above is quoted in full from the FDA-approved drug label published by openFDA, effective June 26, 2026. Matched to this product by RxNorm code. Cross-references to other sections of the full prescribing information have been removed, since they point to a document not shown here. Nothing else is changed: no sentence is shortened, reworded or summarised.